Bradley Showers Operation and Service Instructions
Program the Circuit Board (Figure 14 Continued)
Remove circuit board from housing
NOTE: Follow the procedure below only when you want to access the SEC
and MODE pushbuttons to program cycle times in increment s of 15
seconds.
1. Remove the pan head screw that secures the access panel to the housing (see Figure below).
IMPORTANT: Do not allow the circuit board to come in cont act with metal surfaces.
Since power is still being supplied to the circuit board, cont act with
metal surfaces can cause the board to short-circuit.
2. Pull the circuit board from the housing to access the MODE and SEC pushbuttons.
Figure 14c